Descripción
Wholesale Single Output Led Switching Power Supply 250w
12v 20A with CE RoHS
Features
1.High Efficiency and good price
2.Built-in EMI filter
3.100% full load burn-in test
4.Low output ripple and noise
5.Protection:Over load/Over voltage/Short circuit
6.LIFETIME WARRANTY




Specifications
| Model Specification | S-250-5 | S-250-12 | S-250-24 | S-250-48 |
| DC output voltage | 5V | 12V | 24V | 48V |
| Output voltage error | ±2% | ±1% | ±1% | ±1% |
| Rated output current | 45A | 20A | 10A | 5A |
| Wave and noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p |
| Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
| DC output power | 225W | 250W | 250W | 205W |
| Efficiency | 79% | 83% | 84% | 86% |
| Adjustable range for DC voltage | 4.5-5.6V | 10-13.2V | 20-26.4V | 41-56V |
| AC input voltage range | 90~132VAC/180~264VAC BY SWITCH 47~63Hz;248~370VDC | |||
| Input current | 6.5A/115V 4A/230V | |||
| AC impulse current | 25A/115V 50A/230V | |||
| Leakage current | <3.5mA/240VAC | |||
| Overload protection | 105%~135%. Type,PULSING HICCUP SHUTDOWN; Reset,auto recovery | |||
| Over-voltage protection | 5.75-6.75V | 13.8-16.2V | 27.6-32V | 57.6-67.2V |
| High-temperature protection | RTH3>=65°C FAN ON<=55°C FAN OFF>=80°CCut off output(5~15V) | |||
| RTH3>=70°C FAN ON<=60°C FAN OFF>=85°CCut off output(24~48V) | ||||
| Temperature coefficient | ±0.03%°C(0~50°C) | |||
| Setup rise hold up time | 200ms,50ms,20ms | |||
| Vibration | 10~500Hz,2G 10min./1cycle,Period for 60min,EACH AXES | |||
| Withstand voltage | Input and output interval,1.5KVAC,Input and enclosure,1.5KVAC,Output and enclosure,0.5KVAC | |||
| Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure,500VAC/100M Ohms | |||
| Working temperature and humidity | -10°C~+50°C,20~90%RH | |||
| Store temperature and humidity | -20°C~+85°C,10~95%RH | |||
| Overall dimension | 215*115*50mm | |||
| Weight | 0.93Kgs /17pcs per carton | |||
| Safety standards | Design refer to UL1012, EN60950-1,EN61347-1,EN-61347-2 approved | |||
| EMC standards | EN55015,EN55022,EN55024,EN61000-2,EN61000-3,EN61547 approved | |||
| Note,1.The testing condition for the parameter above is,230VAC input, rated load,25°C 70%Rh,Humidity | ||||
| 2.Error,include the setting error, line stability and load stability.(Note,5) | ||||
| 3.Wave test,adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting | ||||
| 4.Inlet voltage stability test, when is over load, the lowest voltage of inlet is representative to the highest voltage. | ||||
| 5.Load stability test: The load is from 0% to 100%,others 60%. | ||||
| 6.C2,3,11must be knocked down | ||||